Style 200
Stock on the Standard Flow/Pressure System
Performance
Capacities
7 GPH to 20 GPM – Water
2.6 SCFH to 60 SCFM – Air
Scale
100 mm, 127 mm, 250 mm Direct reading
Accuracy
± 4% of Full Scale Flow, 100 mm scale
± 3% of Full Scale Flow, 127 mm scale
Turndown
10:1 to 12.5:1 unless otherwise indicated
Repeatability
2%, 100 mm scale 2%, 127 mm scale
Max Temperature
Air - 100° F (38° C), Water - 130° F (54° C)
Max Pressure
Water - 125 psig, Air - 100 psig
Ambient Temperature
33° F to 125° F (1° C to 52° C)
Options
Certified Calibrations
Conform to ISA RP 16.6
Liquid & Gas Compatible
Scales
Produced in any volumetric unit
Caution: Meters used in gas service are designed to operate at 14.7 psia. Meters used in pressure gas service must be shielded using 3/8” polycarbonate to protect personnel and equipment in the event of tube failure.